Applications of AC80C-Y Punch Press Special Inverter Solution
Overview
- Overview
- Features and Benefits
- Related Products
- Related Cases
- Related News & Events
- Related Solutions
- Contact us
Applications of AC80C-Y Punch Press Special Inverter Solution
Features and Benefits
Abstract: Veichi AC80C-Y Punch press is a stamping type press. In general, the stamping process is energy-saving and efficient compared with traditional mechanical processing, and the stamping process has less demanding of operating technique and a variety of mold machining products can be made, which is why Veichi AC80C-Y Punch Press Special Inverter is widely used. There is a steady increase in drive speed when punch press has started with no mechanical impact, which protects the mechanical part and extends maintenance time. The speed of Veichi AC80C-Y punch press inverter can be adjusted according to product requirements to ensure product quality and reduce scraps.
1. Working Principle of Punch Press
Punch is mainly used for sheet metal forming. Punching, forming, stretching, trimming, fine blanking, riveting and extrusion can be made by the mold, which are widely used in electronics, telecommunications, home appliances, vehicles and so on.
The principle of the punching machine is to convert circular motion into linear motion. The main motor drives the flywheel and the gear, crankshaft (or eccentric gear), connecting rod are driven through the control of the clutch to achieve linear motion of the mold.
2. Veichi AC80C-Y Features
a. Compact structure, optimized structure design with reduced the volume.
b. High reliability, temperature test, long life design, wide voltage input, three anti-paint automatic spraying process.
c. Unique voltage suppression capability to quickly restrain the DC terminal bus voltage.
d. Unique current suppression function, wave limit current function inside the hardware to quickly suppress the running current.
e. Steady speed and high precision, wide speed range, large torque in low frequency, strong overload capacity.
f. Fast and stable speed tracking function can track 1Hz speed.
g. Random carrier function, easily deal with electric noise.
3. Electric Wiring Diagram and Parameter Settings
a. Electric wiring diagram:
Note:
(1) When installing a DC reactor, be sure to remove the jumper between P1 and (+) terminal;
(2) Multi-function input terminals (X1 ~ X7 / PUL) can select NPN or PNP transistor as an input signal, and the bias voltage can be the inverter internal power supply(+ 24V terminal) or an external power supply (PLC terminal). The illustrated switch pulling to +24 indicates "+ 24V" and "PLC" is in short-circuited state.
(3) Analog monitor outputs are the special output for frequency meter, ammeter, voltmeter and other special meters, and the analog monitor output cannot be used in control type operation such as feedback control.
(4) Due to the presence of various types of pulses, the specific wiring methods please see in detailed description.
b. Parameter settings:
(1) Motor parameter setting
Function code |
Setting |
Function code name |
F0.00 |
0 |
Control method |
F5.01 |
XX |
Motor poles |
F5.02 |
XX |
Motor rated power |
F5.03 |
XX |
Motor rated frequency |
F5.04 |
XX |
Motor rated speed |
F5.05 |
XX |
Motor rated voltage |
F5.06 |
XX |
Motor rated current |
(2) Function parameters:
Function code |
Setting |
Function code name |
F0.02 |
1 |
Running command channel |
F0.03 |
2 |
Frequency given main channel selection |
F0.09 |
XX |
Maximum frequency |
F0.11 |
XX |
Upper limit frequency |
F0.12 |
XX |
Lower limit frequency |
F0.14 |
XX |
Acceleration time 1 |
F0.15 |
XX |
Deceleration time1 |
F0.17 |
XX |
Carrier frequency |
F3.22 |
1 |
AO1 output |
(3) AO2 output pulse parameter and communication parameters:
Function code |
Setting |
Function code name |
F0.02 |
2 |
Running command channel |
F0.03 |
6 |
Control mode |
F3.23 |
1 |
AO2 output |
F3.26 |
3 |
AO2 signal selection |
F3.29 |
XX |
AO2FM frequency output lower limit |
F3.30 |
XX |
AO2FM frequency output upper limit |
Fd.00 |
0 |
Main slave selection |
Fd.01 |
XX |
Native address |
Fd.02 |
XX |
Communication baud rate selection |
Fd.03 |
XX |
Data form |
Note: PLC control pulse input parameters and communication parameters would be set if necessary.
4. Summary